[an error occurred while processing this directive] [an error occurred while processing this directive] [an error occurred while processing this directive]
[an error occurred while processing this directive]
导弹与制导技术

转台安装误差对光学捷联惯导标定的影响分析

  • 丁枫 ,
  • 冯丽爽 ,
  • 晁代宏 ,
  • 宋来亮
展开
  • 北京航空航天大学仪器科学与光电工程学院,北京 100191

丁枫(1985-),男,黑龙江人,硕士研究生,研究方向:光纤捷联惯导相关技术。

收稿日期: 2012-05-18

  网络出版日期: 2025-05-24

The Influence of Turntable Fixing Errors on Optical Gyro Strapdown Inertial System Calibration

  • DING Feng ,
  • FENG Lishuang ,
  • CHAO Daihong ,
  • SONG Lailiang
Expand
  • School of Instrument Science and Opto-electronics Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100191, China

Received date: 2012-05-18

  Online published: 2025-05-24

摘要

针对双轴转台标定时安装误差对光学捷联惯导标定的影响,推导了双轴转台安装误差与标定参数的数学关系,分析并量化了转台安装水平误差、方位误差对标定结果的影响。得到以下结论:转台安装误差对陀螺标定结果与加速度计零偏标定结果没有影响;当转台安装水平误差为11´时,加速度计标度因数误差为10-5;假定加速度计真实失准角为5′,转台水平误差为1°,则标定后的加速度计失准角误差仅为0.1”。结论可作为修正双轴转台安装误差的理论依据。

本文引用格式

丁枫 , 冯丽爽 , 晁代宏 , 宋来亮 . 转台安装误差对光学捷联惯导标定的影响分析[J]. 弹箭与制导学报, 2013 , 33(1) : 19 -24 . DOI: 10.15892/j.cnki.djzdxb.2013.01.002

Abstract

The mathematic relations between fixing error of two-axis turntable and the calibration parameters were derived for analyzing the influence of the fixing errors of turntable on the optical gyro strapdown inertial system calibration. The influence of the horizontal and the orientational fixing errors of turntable on the calibration parameters were analyzed quantificationally. The conclusions are drawn as follows: fixing errors of turntable have no influence on the calibration parameters of three gyros and the biases of three accelerometers. The scale factor errors of three accelerometers are 10-5 when the horizontal error is 11´. Assuming real misalignment angles of three accelerometers are 5 and the horizontal error of turntable is 1º, the calibration errors of misalignment angles are only 0.1". The results can be applied to adjusting the two-axis turntable.

[an error occurred while processing this directive]

参考文献

[1]
Dongkyu Lee,Sangchul Lee,et al. Test and error parameter estimation for MEMS based low cost IMU calibration[J]. International Journal of Precision Engineering and Manufacturing,2011,12(4): 597 - 603.
[2]
肖龙旭,魏诗卉,孙文胜.惯测组合快速高精度标定方法研究[J]. 宇航学报,2008,29(1): 172 - 177.
[3]
严恭敏,秦永远.激光捷联惯组的双轴位置转台标定仿真[J]. 中国惯性技术学报,2007,15(1): 123 - 127.
[4]
张红良. 惯性测量组合零偏的一种现场标定方法[J]. 弹箭与制导学报, 2009, 29(4): 4- 7.
[5]
肖桂平. 光学陀螺捷联惯导系统的标定精度分析[D]. 长沙: 国防科技大学, 2008.