固体推进剂过载大应变及加速度存储测试系统设计

  • 曲兵兵 ,
  • 孔德仁 ,
  • 王芳 ,
  • 范徽
展开
  • 南京理工大学机械工程学院,南京 210094

曲兵兵(1986-),女,黑龙江人,硕士研究生,研究方向:动态测试与智能仪器。

收稿日期: 2012-12-13

  网络出版日期: 2025-05-26

Memory Test System Design of Large Strain and Overload Acceleration for Solid Propellant

  • QU Bingbing ,
  • KONG Deren ,
  • WANG Fang ,
  • FAN Hui
Expand
  • School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China

Received date: 2012-12-13

  Online published: 2025-05-26

摘要

针对固体火箭推进剂在过载状态下的药柱大应变及过载加速度测试中,存在应变计及加速度传感器引线困难、实际操作复杂等问题,提出利用存储测试技术方法设计一种基于FPGA的小体积、多通道、可程控的存储测试装置。设计的存储测试系统能够完成对大应变及加速度信号的采样、存储、传输、数据处理及波形显示,该装置对固体发动机工作过程中的药柱安全评估监测及诊断具有一定的优势和工程应用价值。

本文引用格式

曲兵兵 , 孔德仁 , 王芳 , 范徽 . 固体推进剂过载大应变及加速度存储测试系统设计[J]. 弹箭与制导学报, 2013 , 33(5) : 126 -128 . DOI: 10.15892/j.cnki.djzdxb.2013.05.023

Abstract

To solve the difficulty and complex operation of lead in strain gauge and the acceleration sensor during measuring the large strain of grain and the acceleration of overload solid rocket propellant, a storage test system device was proposed based on programmable FPGA with small volume and multi-channel. This miniature memory test system is able to complete sampling, storage, transmission, data processing and waveform display of large strain and acceleration signal. The device has certain advantages and value in engineering applications for safety assessment monitoring of grain and diagnosis in solid engine work process.

[an error occurred while processing this directive]

参考文献

[1]
朱卫兵. 固体火箭发动机药柱结构完整性及可靠性分析[D]. 哈尔滨: 哈尔滨工程大学, 2005.
[2]
孔德仁, 朱蕴璞, 狄长安. 工程测试技术[M].2版. 北京: 科学出版社, 2009.
[3]
马良珵. 应变电测与传感技术[M]. 北京: 中国计量出版社, 1993.
[4]
吴丽娟. 基于串行闪存的数据采集存储系统的研究[D]. 太原: 中北大学, 2010.
[5]
阮晓峰. 药柱大应变测量方法研究[D]. 南京: 南京理工大学, 2012.