[an error occurred while processing this directive]
相关技术

区截测速系统校准及测量不确定度的评定方法

  • 易春林 ,
  • 赵传荣 ,
  • 周岚 ,
  • 张皋 ,
  • 吕永柱
展开
  • 1 西安近代化学研究所, 西安 710065
    2 南京理工大学机械工程学院, 南京 210094

易春林(1962-),男,陕西西安人,高级工程师,研究方向:虚拟试验及靶场测试技术。

收稿日期: 2014-11-04

  网络出版日期: 2025-05-28

基金资助

基础科研项目(J092010B002)

The Assessment Method of Zone-block Velocity Measuring System's Calibration and Measuring Uncertainty

  • YI Chunling ,
  • ZHAO Chuanrong ,
  • ZHOU Lan ,
  • ZHANG Gao ,
  • LYU Yongzhu
Expand
  • 1 Xi'an Modern Chemistry Research Institute, Xi'an 710065, China
    2 School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China

Received date: 2014-11-04

  Online published: 2025-05-28

摘要

针对现有区截测速系统不确定度的评定方法没有考虑被校系统动态特性的问题,基于统计学原理分别研究了影响区截测速系统速度测量不确定度各因素的评定方法,建立了区截测速系统速度测量不确定度的评定模型。选用外弹道飞行特性优良的某型“标准”弹道枪为速度源进行多发校准实验,采用上述不确定度的评定模型对实验数据进行分析,获得了被校区截测速系统速度测量不确定度的值,说明该评定模型具有一定的工程意义。

本文引用格式

易春林 , 赵传荣 , 周岚 , 张皋 , 吕永柱 . 区截测速系统校准及测量不确定度的评定方法[J]. 弹箭与制导学报, 2015 , 35(5) : 181 -183 . DOI: 10.15892/j.cnki.djzdxb.2015.05.041

Abstract

In view of the problems of present evaluation methods of zone-block velocity measuring system that not considering dynamic characteristics of calibrated system, assessment method of factors which affect speed measuring uncertainty were respectively researched and the system's velocity measuring uncertainty assessment model was established based on statistical principle. Calibration experiments were carried out by choosing certain type of "standard" ballistic gun of good exterior ballistic flight characteristics as the source of speed. Based on above assessment model, the experimental data was analyzed, and the chosen zone-block velocity measuring system's measurement uncertainty value was obtained, which illustrates the engineering significance of this assessment model.

[an error occurred while processing this directive]

参考文献

[1]
刘世平. 弹丸速度测量与数据处理[M]. 北京: 兵器工业出版社, 1994: 1-2.
[2]
朱莹, 李永成, 朱公柏. 弹丸测速装定技术[J]. 兵工自动化, 2006, 25 (6): 22-23.
[3]
宋斌, 杨润泽, 张治, 等. 破片区截测速方法发展现状及趋势[J]. 科技与向导, 2013, (30): 57-57.
[4]
倪晋平, 崔长青, 田会, 等. 四光幕交汇立靶测试系统及纸靶校准方法[J]. 西安工业学院学报, 2004, 24 (4): 319-323.
[5]
高东明. 浅谈对校准工作的认识[J]. 中国计量, 2007 (11): 8-9.
[6]
乔新愚. 两点式速度测量仪校准方法研究[J]. 电子质量, 2011 (5): 70-74.
[7]
邬晶, 王铁岭, 王松. 天幕靶测速系统标定技术的研究[J]. 中国测试, 2009, 35 (1): 114-117.
[8]
章启成, 孔德仁, 庞忠根, 等. 弹丸速度测量系统校准方法研究[J]. 南京理工大学学报, 2010, 34 (1): 96-98.
[9]
马春浩. 破片速度测量系统校准方法研究[D]. 南京: 南京理工大学, 2013.