[an error occurred while processing this directive] [an error occurred while processing this directive] [an error occurred while processing this directive]
[an error occurred while processing this directive]
弹药技术

爆炸场热通量与温度的理论与实验研究

  • 陈爱艳 ,
  • 范锦彪 ,
  • 李玲玲
展开
  • 1 中北大学电子测试技术国家重点实验室,太原 030051
    2 仪器科学与动态测试教育部重点实验室,太原 030051

陈爱艳(1989-),女,山西太原人,硕士研究生,研究方向:爆炸场瞬态温度的研究。

收稿日期: 2014-11-06

  网络出版日期: 2025-05-28

The Theoretical and Experimental Research Between Heat Flux and Temperature in Blasting Field

  • CHEN Aiyan ,
  • FAN Jinbiao ,
  • LI Lingling
Expand
  • 1 National Key Laboratory for Electronic Measurement Technology, North University of China, Taiyuan 030051, China
    2 Key Laboratory of Instrumentation Science and Dynamic Measurement( North University of China) Ministry of Education, Taiyuan 030051, China

Received date: 2014-11-06

  Online published: 2025-05-28

摘要

由于爆炸场的环境特殊,从而使测量的温度比实际要偏低。故研究热通量与温度的关系,通过测量热通量得到更加准确的爆炸场温度。论文从理论上研究分析了热通量与温度之间的关系,通过测试系统对爆炸场的热通量和温度进行了实际测量,并进行了实验分析。最终得出通过测量的热通量换算得到的温度比直接测量得到的温度更能真实地反应爆炸场的爆温。

关键词: 爆炸场; 热通量; 温度

本文引用格式

陈爱艳 , 范锦彪 , 李玲玲 . 爆炸场热通量与温度的理论与实验研究[J]. 弹箭与制导学报, 2015 , 35(5) : 69 -71,75 . DOI: 10.15892/j.cnki.djzdxb.2015.05.018

Abstract

Because of special environment in blasting filed, the measured temperature is lower than actual temperature. By studying the relationship between heat flux and temperature, accurate temperature was got through the measured heat flux. In the paper, the relationship between heat flux and temperature was analyzed theoretically; the experimental result of heat flux and temperature that got through test system was analyzed. The temperature converted from the measured heat flux can more realistically reflect explosion temperature than the measured temperature.

[an error occurred while processing this directive]

参考文献

[1]
Baker W E,Cox P A,Westine P S,et al. Explosion hazards and evaluation [M]. Amsterdam: Elsevier,1983.
[2]
Rakaczky J A. The suppression of thermal hazards from explosions of munitions: A literature survey. BRL Interim Memorandum Report,No. 377 [R]. 1975.
[3]
陈云珠,崔志尚,孙坚. 热通量传感器的应用及检定[J]. 中国高新技术企业,2011( 9) : 79-81.
[4]
尹福炎 热流传感器及其应用概况[J]. 传感器世界, 2000 (11): 7-43.
[5]
余凯凯 基于 ZigBee 无线传感网络瞬态温度存储测试系统的研究[D]. 太原: 中北大学, 2011.
[6]
黄磊, 何中其, 李春光, 等. 热通量传感器在爆炸场热辐射测试中的应用[J]. 火炸药学报, 2011, 34 (5): 38-42.
[7]
田壮,温济霞,祖静,等. 瞬态高温测试系统的设计[J]. 伺服控制,2012(3): 89-91.
[8]
郑燕露,张会新,李永慧. 基于FPGA 的高温热流传感器信号采集系统设计[J]. 化工自动化及仪表,2011, 38(7): 809-811.
[9]
黄磊. 不同炸药爆源的爆炸场热效应分析与测试[D]. 南京: 南京理工大学,2013: 19-20.
文章导航

/

[an error occurred while processing this directive]