[an error occurred while processing this directive] [an error occurred while processing this directive] [an error occurred while processing this directive]
[an error occurred while processing this directive]
弹药技术

适用于高旋弹药的MIMU角速率解算算法研究

  • 王博 ,
  • 李杰 ,
  • 于希宁 ,
  • 杜英
展开
  • 中北大学电子测试技术国家重点实验室,太原 030051

王博(1984-),男,山西运城人,硕士研究生,研究方向:惯性测量技术。

收稿日期: 2010-02-24

  网络出版日期: 2025-05-28

基金资助

国家自然科学基金(50675313);国家自然科学基金(50905160)

The Research on Angular Velocity Solution Algorithm of MIMU for High Rotation Ammunition

  • WANG BO ,
  • LI Jie ,
  • YU Xining ,
  • DU Ying
Expand
  • National Key Laboratory for Electronic Measurement Technology, North University of China, Taiyuan 030051, China

Received date: 2010-02-24

  Online published: 2025-05-28

摘要

针对由于陀螺抗过载能力差限制传统捷联惯性测量系统使用问题,以高速旋转弹药制导化应用为背景,提出了一种十二加速度计配置方案。在分析比较几种常见角速率解算算法基础上,通过优化组合得到了一种特别适用于高旋弹药而且不随时间积累的角速率解算算法,最后利用计算机仿真验证了该算法的有效性。仿真结果表明,该算法不随时间积累发散,在提高角速率解算精度的同时有效避免了角速率解算过程中符号误判和过零震荡现象。

关键词: 加速度计; 角速率; 解算

本文引用格式

王博 , 李杰 , 于希宁 , 杜英 . 适用于高旋弹药的MIMU角速率解算算法研究[J]. 弹箭与制导学报, 2010 , 30(6) : 122 -124,127 . DOI: 10.15892/j.cnki.djzdxb.2010.06.066

Abstract

In view of the limits of gyro's performance and with the background of application in guidance of high rotation ammunition, a scheme with 12 accelerometers was proposed. In this scheme, two kinds of angular velocity solution algorithm were obtained with the help of accelerometers' outputs which restrained errors growing with time. Finally, the deduction process of the novel method was discussed and validity of it was confirmed by simulation results. The simulation results show that the algorithm does not accumulate or transpire over time; to some extent, it also can effectively improve the precision of angular velocity solution. At the same time, the problem of symbol miscarriage of justice in the process of angular velocity solution was solved effectively.

[an error occurred while processing this directive]

参考文献

[1]
牟淑志, 卜雄洙, 李永新, 等. 高转速载体惯性测量组合研究[J]. 弹道学报, 2006, 18 (4): 85- 88.
[2]
丁明理, 王祁. 无陀螺惯性测量组合研究现状概述[J]. 中国惯性技术学报, 2005, 13 (4): 83- 88.
[3]
赵龙, 陈哲. 提高无陀螺捷联惯导系统角速度解算精度的新方法[J]. 系统仿真学报, 2005, 15 (4): 579- 603.
[4]
覃方君, 许江宁, 李安,等. 一种准无陀螺惯导系统解算新方法研究[J]. 系统仿真学报, 2008, 20 (1): 49- 52.
[5]
薛红香, 夏全喜, 孙明,等. 无陀螺惯性测量单元设计及仿真分析[J]. 中国惯性技术学报, 2008, 16 (2): 154- 158.
[6]
郝燕玲, 刘志平. 无陀螺捷联惯导系统角速度解算新方法[J]. 弹箭与制导学报, 2009, 29 (4): 35- 38.
[7]
周百令. 一种新型的单陀螺多加速度计捷联惯导系统[J]. 中国惯性技术学报, 2002, 10 (1): 6- 9.
[8]
曹咏弘, 祖静, 林祖森. 无陀螺捷联惯导系统综述[J]. 测试技术学报, 2004, 18 (3): 269- 273.
[9]
汪小娜, 王树宗, 朱华兵. 无陀螺捷联惯导系统加速度计安装误差研究[J]. 兵工学报, 2008, 29 (2): 159- 163.