相关技术

基于箱式发射技术的定向器有限元分析

  • 王兆飞 ,
  • 杨金柱 ,
  • 崔凯
展开
  • 武警工程学院,西安 710086

王兆飞(1987-),男,安徽太和人,硕士研究生,研究方向:军事装备学、非致命武器。

收稿日期: 2011-05-19

  网络出版日期: 2025-05-29

The Finite Element Analysis of Launch Tube Based on Box-type Missile Launch Technology

  • WANG Zhaofei ,
  • YANG Jinzhu ,
  • CUI Kai
Expand
  • Engineering College of Armed Police Force, Xi'an 710086, China

Received date: 2011-05-19

  Online published: 2025-05-29

摘要

针对多管火箭箱式发射技术的特点,结合其在非致命武器领域的应用,提出了储运与发射非致命火箭弹一体化的箱储式防暴弹发射单元这一全新概念。对发射装置承受载荷进行了分析,选取工程塑料作为定向器材料。利用计算机辅助设计软件Pro/Engineer与有限元分析软件ANSYS相结合,建立了定向器有限元数值仿真模型,对定向器在承受最大载荷状态下的应力变形及位移进行了对比分析,保证了定向器设计符合理论设计要求。

本文引用格式

王兆飞 , 杨金柱 , 崔凯 . 基于箱式发射技术的定向器有限元分析[J]. 弹箭与制导学报, 2012 , 32(1) : 222 -224 . DOI: 10.15892/j.cnki.djzdxb.2012.01.064

Abstract

According to the features of box-type missile launch technology for multi-launch rocket, and its application in non-lethal weapon field, a new concept about the anti-riot rocket's launching unit with integration of storing and launching non-lethal rockets was proposed. The load for the launcher was analyzed and engineering plastics were selected as launch tube material. The computer aided design software Pro/Engineer was combined with the finite analysis software ANSYS, the numerical simulation of the launch tube was established. To ensure the launch tube design consisting with the theoretical design requirements, the stress and displacement of the launch tube under the maximum load were analyzed by comparison.

[an error occurred while processing this directive]

参考文献

[1]
张柏生, 李云娥. 火炮与火箭内弹道原理[M]. 北京: 北京理工大学出版社, 1996.
[2]
李军. 火箭发射系统设计[M]. 北京: 国防工业出版社, 2008.
[3]
姚昌仁, 张波. 火箭导弹发射装置设计[M]. 北京: 北京理工大学出版社, 1998.
[4]
张文志, 韩清凯, 刘亚忠,等. 机械结构有限元分析[M]. 哈尔滨: 哈尔滨工业大学出版社, 2006.
[5]
王国业, 王国军, 胡仁喜. Pro/Engineer Wildfire 5.0中文版机械设计从入门到精通[M]. 北京: 机械工业出版社, 2009.