相关技术

宽视场光学设备畸变修正方法

  • 杨增学 ,
  • 刁小鹏 ,
  • 王康相 ,
  • 王雨
展开
  • 中国华阴兵器试验中心,陕西华阴 714200

杨增学(1964-),男,陕西富平人,高级工程师,研究方向:弹道测量与数据处理。

收稿日期: 2014-01-07

  网络出版日期: 2025-05-30

Distortion Correction Method for Optical Equipment with Wide Field of View

  • YANG Zengxue ,
  • DIAO Xiaopeng ,
  • WANG Kangxiang ,
  • WANG Yu
Expand
  • Huayin Ordnance Test Center of China, Shaanxi Huayin 714200, Chian

Received date: 2014-01-07

  Online published: 2025-05-30

摘要

光学畸变是宽视场光学设备测角精度的主要影响因素,通过深入分析研究现有光学畸变修正方法,提出了基于视场分区标定建立光学畸变多修正多模型的新方法。通过实验表明,该方法可以有效的提高宽视场光学设备的测量精度,特别适用于成像探测器像元尺寸较大的宽视场光学设备的畸变高精度修正,为连发齐射多目标、快速目标、大动态目标等弹道高精度测量提供了技术支撑。

本文引用格式

杨增学 , 刁小鹏 , 王康相 , 王雨 . 宽视场光学设备畸变修正方法[J]. 弹箭与制导学报, 2014 , 34(6) : 173 -176 . DOI: 10.15892/j.cnki.djzdxb.2014.06.044

Abstract

Optical distortion is an important factor which can degrade angle measurement accuracy of optical measuring equipment with wide field of view. In this work, a new multiple-model correction method based on partition calibration was proposed. A corresponding experiment was performed, and its results validate that this method can effectively raise angle measurement accuracy of equipment. It is applicable to optical equipment with large-sized detector pixel, and it would provide practical support for ballistic measurement of automatic salvo multi-targets, high speed targets and large dynamic targets with high accuracy.

[an error occurred while processing this directive]

参考文献

[1]
王家骐. 光学仪器总体设计[M]. 长春: 长春光学精密机械与物理研究所, 2003.
[2]
王之卓. 摄影测量原理[M]. 武汉: 武汉测绘科技大学出版社, 2007.
[3]
Weng JY, Cohen P, Herniou M. Camera calibration with distortion models and accuracy evaluation[J]. IEEE Trans on Pattern Analysis and Machine Intelligence, 1992, 14(10): 965-980.
[4]
杨增学. 常规兵器试验交会测量方法及应用[M]. 西安: 西安交通大学出版社, 2010.
[5]
费业泰. 误差理论与数据处理[M]. 第4版. 北京: 机械工业出版社, 2005.