某隔板点火装置点火延迟时间超差分析与改进

  • 程翔 ,
  • 黄少波 ,
  • 邢国强 ,
  • 沈欣
展开
  • 1 中国空空导弹研究院第四研究所, 河南 洛阳 471009
    2 驻中国空空导弹研究院军事代表室, 河南 洛阳 471009

程翔(1983-),男,河南洛阳人,工程师,研究方向:火工品技术研究。

收稿日期: 2018-04-09

  网络出版日期: 2025-05-20

Analyse and Improve on Ignition Delay Time Tolerance of Bulkhead Igniter

  • CHENG Xiang ,
  • HUANG Shaobo ,
  • XING Guoqiang ,
  • SHEN Xin
Expand
  • 1 China Airborne Missile Academy, Henan Luoyang 471009, China
    2 PLA Military Representative Office in China Airborne Missile Academy, Henan Luoyang 471009, China

Received date: 2018-04-09

  Online published: 2025-05-20

摘要

某隔板点火装置出现点火延迟时间超差现象,对此进行了故障分析与复现试验,结果表明:因受主药的加强帽点铆效果差,显著降低了传火药盒的点火压强峰,扩燃药片的点火效果不稳定,导致了点火延迟时间超差。通过改进点铆工装、增加抽检试验项目、优化药盒药片安装位置、加厚药盒堵片厚度等措施解决了该故障。

本文引用格式

程翔 , 黄少波 , 邢国强 , 沈欣 . 某隔板点火装置点火延迟时间超差分析与改进[J]. 弹箭与制导学报, 2019 , 39(3) : 69 -71,80 . DOI: 10.15892/j.cnki.djzdxb.2019.03.016

Abstract

In order to solve the ignition delay time tolerance of a bulkhead igniter by failure analysis and fault recurrence, the results showed that: The impact of point riveting on strengthening cap was weakened, which Obvious decreased the ignition pressure peak of flame combustion chamber, slowed down the ignition effect of ignition tablet. By improve the point riveting tooling, increase sampling inspection, adjust the position of ignition tablet, increase the thickness of blocking piece, the failure has removed.

[an error occurred while processing this directive]

参考文献

[1]
苌军红, 李便花, 潘会平,等. 某型火工品作用失效研究[J]. 新技术新工艺, 2017 (3): 78- 81.
[2]
索亮, 杜晓臣, 梁珂,等. 某点火具延期时间超差的原因与改进[J]. 火工品, 2016 (5): 25- 27.
[3]
李便花, 潘会平, 孔峻峰,等. 某型作动类火工品作用失效研究[J]. 新技术新工艺, 2016 (3): 97- 99.
[4]
杨正才, 廖昕, 李晓刚,等. 某隔板起爆器冲击起爆过程的数值模拟与实验研究[J]. 含能材料, 2011, 19 (2): 221- 225.
[5]
饶豫鄂, 张爱华, 魏国. BPN 点火药的分析方法研究[J]. 火工品, 2003 (2): 50- 52.
[6]
矢野裕, 杜力. B/KNO3点火药的燃速特性[J]. 火工情报, 1998 (2): 46- 51.
[7]
姚朴. 火工品药剂吸湿性测定法: WJ1865–1989[S]. 北京: 机械电子工业部兵器标准化所, 1989.
[8]
高滨, 马景, 杨谋祥, 等. 航天火工装置通用规范:GJB1307A-2004[S]. 北京: 国防科学技术工业委员会, 2004.