[an error occurred while processing this directive] [an error occurred while processing this directive] [an error occurred while processing this directive]
[an error occurred while processing this directive]
CORRELATION TECHNOLOGY

The Analysis on Accelerometer Scale Factor Test Result Difference

  • ZHAO Junzhe ,
  • OUYANG Heng ,
  • ZHANG Penghao ,
  • WEI Feiyan
Expand
  • 1 Changcheng Institute of Metrology and Measurement, AVIC, Beijing 100095, China
    2 No. 203 Research Institute of China Ordnance Industries, Xi'an 710065, China

Received date: 2012-08-11

  Online published: 2025-05-26

Abstract

In order to find the reason why 0. 1μΑ/g difference occurs between the a accelerometer's scale factor survey results and the delivery result, this article begins with the accelerometer scale factor test and calculation method, combined with automatic test system composition and testing principle, the scale factor uncertainty was evaluated. The conclusion is measurement uncertainty of the testing device itself causes different test result.

Cite this article

ZHAO Junzhe , OUYANG Heng , ZHANG Penghao , WEI Feiyan . The Analysis on Accelerometer Scale Factor Test Result Difference[J]. Journal of Projectiles, Rockets, Missiles and Guidance, 2013 , 33(2) : 167 -168,172 . DOI: 10.15892/j.cnki.djzdxb.2013.02.051

[an error occurred while processing this directive]

References

[1]
董雪明 加速度计自动测试系统[J]. 计测技术, 2000,20 (2): 19- 21.
[2]
徐永 加速度计自动测试系统研制总结报告[R]. 中航工业计量所, 2004.
[3]
GJB 1037A-2004 单轴摆式伺服线加速度计试验方法[S].
[4]
沙定国, 刘智敏. 测量不确定度的表示方法[M]. 北京: 中国科学技术出版社, 1994.
[5]
李宗扬. 计量技术基础[M]. 北京: 原子能出版社, 2002.
Outlines

/

[an error occurred while processing this directive]